Charity Golf Network

Your source for information about hosting a charity golf tournament.

Micrologic 5.0 trip unit

>> Download Micrologic 5.0 trip unit


>> Read Online Micrologic 5.0 trip unit













The Micrologic 1 and 2 trip units are described in the Compact NSX circuit breakers - User manual. Micrologic 2.2 100 A trip unit. The contactor can be closed again automatically or manually depending on the setting of the SDTAM Module (see the bulletin shipped with the circuit breaker for filexlib. The Micrologic P trip unit has a default bar graph display of currents and three different menus which can be accessed using navigation buttons: A. Bar Graph Display—Provides real-time bar graph display of line currents and measurement of line current and neutral current (if applicable) (default display) B. Metering Menu—Provides access to metered values of current, voltage, power, energy and frequency C. Maintenance Menu—Allows user to change the trip unit configuration and provides Schneider Electric Thailand. 33554 - Circuit breaker, ComPact NS800L, 150kA/415VAC, Micrologic 5.0 trip unit, 800A, fixed, 3 poles 3d.
The Micrologic X control unit includes: Micrologic X status LEDs. A local HMI comprising a graphic display with colored backlight, contextual buttons, and dedicated buttons. LEDs to monitor circuit breaker operations as well as the source of trips and alarms.
The Schneider Electric Trip Unit 33070-3 is designed to provide a protective measure for specific circuits to be switched out of service quickly and reliably. Its micrologic 5.0 circuit design increases the unit's accuracy in identifying faults, while reducing false trips caused by environmental factors such as lightning or overexcited
Trip unit: Trip unit name: Micrologic 5.0 E: Trip unit technology: Electronic: range compatibility: ComPact NS1600b3200 ComPact NS630b1600: Device application: Distribution: Number of poles: 3P 4P: Protected poles description: 3t 3t + N/2 4t: Trip unit protection functions: Selective protection:
Micrologic 5 / 6 A (Ammeter) or E (Energy) trip units can be used on PowerPact H-, J-, and L-frame circuit breakers with performance levels D, G, J, or L.They offer basic LSI protection (Micrologic 5 trip unit) or LSI and ground-fault protection G (Micrologic 6 trip unit).They also … Not finding what you're looking for?
Find many great new & used options and get the best deals for micrologic 5.0 and 6.0 electronic trip unit manual instructions schneider elect at the best online prices at eBay! Free shipping for many products!
Setting the Micrologic 6.0 A/E control unit 7 Setting the Micrologic 7.0 A control unit 8 Selecting the type of neutral protection 9. Discovering the functions 10. Current protection 0 Overload and fault indications 4 Measurements 5 Trip history and pre-alarms 7. Using the HMI 18. HMI display modes 8 Quick View mode (Micrologic E) 20.
Tutorial for testing Micrologic Trip Units in both manual and automatic mode using the Full Function Test Kit (FFTK), catalog number S33595, typically used with Micrologic Trip Units installed in
MicroLogic trip systems use a set of current transformers (called CTs or sensors) to sense current, a trip unit to evaluate the current, and a tripping solenoid to trip the circuit breaker. Adjustable rotary switches on the trip unit allow the user to set the proper overcurrent or equipment ground-fault current protection required in the electrical system.
MicroLogic trip systems use a set of current transformers (called CTs or sensors) to sense current, a trip unit to evaluate the current, and a tripping solenoid to trip the circuit breaker. Adjustable rotary switches on the trip unit allow the user to set the proper overcurrent or equipment ground-fault current protection required in t

Comment

You need to be a member of Charity Golf Network to add comments!

Join Charity Golf Network

© 2025   Created by Tom King.   Powered by

Report an Issue  |  Terms of Service