Perfect for PAGE and Blotting. The Biometra Eco-Line for two gel sizes "Mini" and "Maxi" is a robust, modular tank system for polyacrylamide gel electrophoresis and tank blotting. The buffer tank can be used with the electrophoresis module for 1 to 4 gels (Mini) or 1 to 2 gels (Maxi) as well as with the blotting module. About Hoefer, Inc. Intelligently designed tools for gel electrophoresis and blotting applications by a company with decades of experience. Consistent and reproducible protein and nucleic acid electrophoretic separations. Wide range of products and accessories to meet any need. Learn More. prev. next. CATALOGS. Two tray options available. Cast 3 pcs of agarose gel in one time. MT-108 is offered as a complete system for the user to cast, and run electrophoresis. including: • 1 x Snow tank and transparent lid. • 1 x MT-G01 (Gel Maker Stand) • 1 x MT-T01 (105x83mm Tray) • 2 x MT-T02 (50x83mm Tray) • 1 x MJ-C01 (Double side comb: 8 teeth x 2 The simple, modular design of miniVE vertical electrophoresis system consolidates all the small parts for electrophoresis and blotting into one convenient unit. Uniform gel temperature is maintained with the tank-style lower buffer chamber. A full tank stabilizes the temperature so that lanes are straight and bands are flat. Instruction Manual For Technical Service Call Your Local Bio-Rad Office or in the U.S. Call 1-800-4BIORAD (1-800-424-6723) run a gel. Bio-Rad also recommends that all Mini-PROTEAN II cell components and accessories be cleaned with a suitable laboratory cleaner (such as Bio-Rad Cleaning Concentrate, catalog number Gel Electrophoresis Labnet's ENDURO™ Gel XL includes all components necessary to cast and run horizontal gels: gel trays, combs, casting stand, gel tank and digital power supply. The migration tank, gel trays and multichannel combs are molded for leak-proof performance and a long service life. The direct connection of the power supply into the gel box eliminates the need for power leads. Prepare gels a. Remove the comb, and rinse the gel wells three times using 1X Running Buffer. b. Remove the white tape near the bottom of the gel cassettes. c. Place the gels in the Bolt™ Mini Gel Tank. d. Fill the gel wells with 1X Running Buffer. 4 Load buffers Fill the Anode and Cathode Chambers with the appropriate 1X Running Buffer. 5 1.1 Introduction The GenBox Mini Electrophoresis Tank runs both GenScript's 10*8 and 10*10 precast gels interchangeably. It can run one or two mini gels. The mini tank is compatible with GenBox mini blot modules for tank blotting. Note: 10*8 Gel Buffer Dam (L00699) is optional for purchase, please contact GenScript for details. 2. Remove the lid and unlock the Gel Tension Lever. There is no need to remove the Gel Tension Wedge. 3. Remove the gel cassettes from the mini-cell. Handle gel cassettes by their edges only. 4. Lay the gel cassettes (well side up) on a flat surface, such as the benchtop. Allow one edge to hang ~1 cm over the side of the benchtop. 5. a.emove the comb, and rinse the gel wells three times with 1X NativePAGE™ Dark R Blue Cathode Buffer. b. Remove the white tape near the bottom of the gel cassettes. Place the gels in the XCell SureLock® Mini-Cell gel running tank. d. Fill the gel wells with 1X NativePAGE™ Dark Blue Cathode Buffer. 4 Load samples and standards The Azure Aqua Quad Mini-Cell is designed for running 1-4 precast or handcast gels (cassette size 10cm x 8cm) for electrophoresis. The locking side fasteners pr
© 2024 Created by Tom King. Powered by
You need to be a member of Charity Golf Network to add comments!
Join Charity Golf Network